New
-
New
-
New
-
New
Fuji
Fuji APERTO Lucent MRI
Fuji APERTO Lucent MRI
The Fuji APERTO Lucent is a high-performance 0.4T mid-field open MRI system designed to deliver patient comfort, reliable image quality, and efficient workflow in a space-saving configuration. With IP-Recon, RADAR motion artifact reduction, RF FatSat, VASC-ASL non-contrast blood flow visualization, and high-sensitivity solenoid coils, APERTO Lucent supports a wide range of neuro, vascular, orthopedic, and body imaging applications.
Questions?

Collapsible content
Product Description

Fuji APERTO Lucent Open MRI System – High-Performance Mid-Field MRI
The Fuji APERTO Lucent MRI System is a mid-field open MRI designed for imaging centers and healthcare facilities that want dependable diagnostic performance with a more comfortable patient experience. Its open design helps reduce patient anxiety while allowing easier access for technologists, caregivers, and patients who may be claustrophobic, elderly, pediatric, bariatric, or mobility-limited.

Built around a 0.4T permanent, self-shielded magnet, APERTO Lucent offers a space-saving MRI platform with no helium requirement and simplified siting needs compared with many superconductive MRI systems. The system also includes advanced Fujifilm imaging technologies such as IP-Recon, RADAR, RF FatSat, and VASC-ASL to support image quality, motion reduction, and clinical flexibility.
Key Features of the Fuji APERTO Lucent
0.4T Mid-Field Open MRI Design
APERTO Lucent combines open MRI comfort with a 0.4T field strength, giving facilities a practical imaging solution for routine diagnostic MRI exams.
Permanent Magnet Technology
The system uses a permanent, self-shielded magnet with no helium requirement, helping reduce infrastructure complexity and long-term operating considerations.
Space-Saving Siting Requirements
APERTO Lucent is designed for efficient installation with minimal room dimensions of approximately 17'5" by 13'2", helping facilities maximize available space.
Wide Lateral-Shift Floating Table
The wide floating table supports up to 500 lb and lowers to 20 inches, helping improve patient access, positioning, and technologist workflow.
RADAR Motion Artifact Reduction
RADAR radial scan technology helps reduce motion artifacts from patient movement, minimizing rescans and improving the patient experience.

IP-Recon Image Reconstruction
IP-Recon iterative reconstruction helps boost SNR and supports excellent spatial resolution across neuro, vascular, and orthopedic imaging applications.

RF FatSat and Multi-Channel Shimming
RF FatSat and active multi-channel shimming help enhance image contrast and provide fat suppression for MSK and neuro imaging applications.
VASC-ASL Non-Contrast MRA
VASC-ASL enables non-contrast 3D blood flow visualization for applications such as carotid, renal, portal vein, and extremity vascular imaging.
High-Sensitivity Solenoid Coils
Specialized solenoid coils help improve signal capture and resolution for small field-of-view imaging, with coil options for head, wrist, shoulder, knee, body, and general-purpose applications.
Ideal Clinical Applications
The Fuji APERTO Lucent MRI system is well suited for facilities performing a broad range of MRI studies, including:
- Neuro imaging
- Spine imaging
- Orthopedic and MSK imaging
- Vascular imaging
- Body imaging
- Pediatric MRI
- Claustrophobic or anxious patient exams
- Bariatric and mobility-limited patient imaging
Why Choose the Fuji APERTO Lucent?
The Fuji APERTO Lucent open MRI system gives imaging providers a strong balance of patient comfort, clinical capability, and operational efficiency. Its open design, permanent magnet platform, compact siting requirements, motion reduction technology, and advanced reconstruction tools make it a practical choice for facilities looking to expand MRI access while controlling infrastructure demands.
Key Benefits
- 0.4T high-performance mid-field open MRI
- Open architecture supports patient comfort and accessibility
- Permanent magnet design requires no helium
- RADAR helps reduce motion artifacts and rescans
- IP-Recon supports improved SNR and spatial resolution
- Space-saving design helps reduce siting complexity
Specifications
FUJIFILM APERTO LUCENT
High Performance Mid-Field Open MRI
Technical Specifications
SYSTEM OVERVIEW
• 0.4T open MRI system
• Permanent magnet design
• Single-pillar wide open architecture
• Designed for comfort, value, and advanced imaging capability
• Space-saving design for limited room requirements
• Patient-comforting 320° open patient view
• No helium required
MAGNET SYSTEM
• Field Strength: 0.4T
• Magnet Type: Permanent magnet
• Magnet Design: Self-shielded
• Open MRI configuration
• Active multi-channel shimming
• Vertical field design
• No cryogens / helium required
PATIENT TABLE & POSITIONING
• Wide lateral-shift floating table
• Patient Capacity: Up to 500 lbs
• Table Low Position: 20"
• Lateral table shift for easier isocenter positioning
• Designed for fast, comfortable patient transitions
• Open access for technologist and patient partner support
IMAGING TECHNOLOGIES
• IP-Recon iterative reconstruction
• RADAR™ radial scan motion compensation
• RF FatSat
• Multi-channel shimming
• FatSep Dixon-type fat suppression
• IR-based fat suppression
• VASC-ASL non-contrast MRA
• 3DGEIR optional volume imaging
• Volume Rendering / VR blood flow visualization
ADVANCED APPLICATIONS
• Neuro imaging
• Orthopedic imaging
• Vascular imaging
• Body imaging
• MSK imaging
• Non-contrast angiography
• 3D blood flow visualization
• Motion-corrected imaging
MOTION REDUCTION
• RADAR radial k-space acquisition
• Helps reduce motion artifacts
• Designed to minimize rescans
• Applicable across multiple anatomies, contrasts, and coils
IMAGE RECONSTRUCTION
• IP-Recon de-noising reconstruction
• Iterative reconstruction boosts SNR
• Supports improved spatial resolution
• Designed for neuro, vascular, and orthopedic applications
RF & COILS
• High-sensitivity solenoid coils
• Volume coil design for vertical field imaging
• Designed to maximize signal capture and uniformity
Coil Options / Examples:
• Head
• Knee
• Wrist
• Shoulder
• Flexible Body
• Open Flexible Body
• General Purpose
MRA & VASCULAR IMAGING
• VASC-ASL non-contrast MR angiography
• 3D BASG / balanced SARGE blood flow visualization
• Supports carotid artery imaging
• Supports renal artery imaging
• Supports portal vein imaging
• Supports upper and lower extremity vascular imaging
• MIP and VR vascular reconstruction support
CLINICAL IMAGE EXAMPLES
• Atherosclerotic cerebral infarction
• Basilar aneurysm
• Trigeminal neuralgia
• Vertebral artery dissection
• Glioblastoma
• Renal artery / portal vein MRA
• Hydronephrosis
• Rheumatoid arthritis
• Metastatic liver tumor
• Multiple liver cysts
• Benign prostatic hyperplasia
• Ovarian dermoid cyst
• Cervical spine tumor
• Disk herniation
• Rotator cuff injury
• ACL injury
• Meniscus damage
INSTALLATION & SITING
• Space-saving installation design
• Minimal Room Dimensions: Approx. 17'5" x 13'2"
• Power Requirement: Single Phase 208 VAC
• Power Capacity: 9.5 kVA
• No quench tube required
• No chiller cooling system required
• Equipment room may not be required depending on environment and room layout
GANTRY
• Gantry Weight: 14,800 kg / 32,628 lbs
• Permanent magnet design with fewer infrastructure requirements
• Designed for lower power consumption and reduced maintenance cost
WORKFLOW & SUPPORT
• AutoPose
• AutoExam
• IP-RAPID
• Sentinel Remote Monitoring
• Remote monitoring information collection
• Operation diagnostics
• Maintenance support
KEY FEATURES SUMMARY
• 0.4T permanent open MRI
• 320° patient view single-pillar design
• 500 lb patient table capacity
• 20" low table height
• Lateral table shift
• IP-Recon de-noising reconstruction
• RADAR motion artifact reduction
• RF FatSat
• VASC-ASL non-contrast MRA
• High-sensitivity solenoid coils
• No helium required
• Single phase 208 VAC / 9.5 kVA power
• Compact room requirements
FAQs
Key benefits include open MRI comfort, space-saving siting, lower operating costs, IP-Recon denoising reconstruction, RADAR motion compensation, RF FatSat, VASC-ASL non-contrast blood flow imaging, and high-sensitivity solenoid coils.
Does the APERTO Lucent require helium?No. The APERTO Lucent uses permanent magnet technology and does not require helium, a chiller cooling system, or a quench tube in typical configurations.
Why would an imaging center choose the Fujifilm APERTO Lucent MRI?An imaging center may choose the APERTO Lucent when it needs an affordable open MRI with low siting requirements, no helium, strong patient comfort, motion compensation, fat saturation, non-contrast vascular imaging, and a compact design for smaller imaging facilities.
Additional Information
- Orthopedics
- Spine
- Neuro